Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures
In this project, the viability and adequacy of simultaneous analysis conducted in a single reactional zone of Microfluidic Paper-based Analytical Device (?PAD) though the mixure of 2 or more colorimetric reagents was evaluated for synthetic samples with the concentration range of 0 to 100 ppm for th...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Online |
| Language: | Portuguese |
| Published: |
Universidade Estadual de Campinas
2019
|
| Subjects: | |
| Online Access: | https://econtents.sbu.unicamp.br/eventos/index.php/pibic/article/view/1978 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1864358954790813696 |
|---|---|
| author | Santos, Wendel Rossi, Adriana |
| author_facet | Santos, Wendel Rossi, Adriana |
| author_sort | Santos, Wendel |
| collection | Portal de Eventos Científicos da UNICAMP |
| container_reference | Revista dos Trabalhos de Iniciação Científica da UNICAMP; n. 27 (2019): Congresso de Iniciação Científica UNICAMP; 1-1 |
| description | In this project, the viability and adequacy of simultaneous analysis conducted in a single reactional zone of Microfluidic Paper-based Analytical Device (?PAD) though the mixure of 2 or more colorimetric reagents was evaluated for synthetic samples with the concentration range of 0 to 100 ppm for the analytes. The analytical system used in this research was based on a combination of the aluminum chloride method to quantify flavonoids through complex formation and the Folin-Ciocalteu reagent method to quantify the total phenolic content through redox reactions. Both methods were adapted from their original spectrophotometric systems to new microfluidic ones. |
| first_indexed | 2025-10-08T13:55:58Z |
| format | Online |
| id | ojs-article-1978 |
| institution | Universidade Estadual de Campinas |
| issn | 2596-1969 |
| language | por |
| last_indexed | 2025-10-08T13:55:58Z |
| publishDate | 2019 |
| publisher | Universidade Estadual de Campinas |
| record_format | ojs |
| spelling | ojs-article-19782025-09-26T14:39:16Z Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures Santos, Wendel Rossi, Adriana Microfluidic Simultaneous analysis μPAD In this project, the viability and adequacy of simultaneous analysis conducted in a single reactional zone of Microfluidic Paper-based Analytical Device (?PAD) though the mixure of 2 or more colorimetric reagents was evaluated for synthetic samples with the concentration range of 0 to 100 ppm for the analytes. The analytical system used in this research was based on a combination of the aluminum chloride method to quantify flavonoids through complex formation and the Folin-Ciocalteu reagent method to quantify the total phenolic content through redox reactions. Both methods were adapted from their original spectrophotometric systems to new microfluidic ones. Universidade Estadual de Campinas 2019-11-30 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artigo de convidado application/pdf https://econtents.sbu.unicamp.br/eventos/index.php/pibic/article/view/1978 10.20396/revpibic2720191978 Revista dos Trabalhos de Iniciação Científica da UNICAMP; n. 27 (2019): Congresso de Iniciação Científica UNICAMP; 1-1 2596-1969 por https://econtents.sbu.unicamp.br/eventos/index.php/pibic/article/view/1978/2036 Copyright (c) 2019 Revista dos Trabalhos de Iniciação Científica da UNICAMP http://creativecommons.org/licenses/by/4.0 |
| spellingShingle | Santos, Wendel Rossi, Adriana Microfluidic Simultaneous analysis μPAD Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title | Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title_full | Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title_fullStr | Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title_full_unstemmed | Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title_short | Viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| title_sort | viability of simultaneous analysis through reagent mixture in microfluidic paper-based analytical devices using colorimetric measures |
| topic | Microfluidic Simultaneous analysis μPAD |
| url | https://econtents.sbu.unicamp.br/eventos/index.php/pibic/article/view/1978 |
| work_keys_str_mv | AT santoswendel viabilityofsimultaneousanalysisthroughreagentmixtureinmicrofluidicpaperbasedanalyticaldevicesusingcolorimetricmeasures AT rossiadriana viabilityofsimultaneousanalysisthroughreagentmixtureinmicrofluidicpaperbasedanalyticaldevicesusingcolorimetricmeasures |