Determination of Tadalafil in pharmaceutical preparation of combination therapy with complex of vitamins and minerals by HPLC-UV detector
The method of determining Tadalafil in a mixture with a complex of vitamins and minerals by HPLC was verified to be linear, precise, selective and accurate with the use of WATERS Nova-Pack® C8 (3.9x150) mm; 4 ?m column. The mobile phase used was water:acetonitrile:trifluoroacetic acid (60:40:0.1) at...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Online |
| Language: | Portuguese |
| Published: |
Universidade Estadual de Campinas
2019
|
| Subjects: | |
| Online Access: | https://econtents.sbu.unicamp.br/eventos/index.php/pibic/article/view/2048 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | The method of determining Tadalafil in a mixture with a complex of vitamins and minerals by HPLC was verified to be linear, precise, selective and accurate with the use of WATERS Nova-Pack® C8 (3.9x150) mm; 4 ?m column. The mobile phase used was water:acetonitrile:trifluoroacetic acid (60:40:0.1) at the flow rate of 1 mL/min with UV detection at 285 nm at ambient temperature. Linearity was determined between 0.08 and 0.11 mg/mL with a correlation factor of 0.998. Standard deviations of performed tests of precision and accuracy were insignificant and components of the matrix did not interfere in the retention time of Tadalafil, the method is selective. |
|---|---|
| ISSN: | 2596-1969 |