Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence

In the present work we used a MEGA-PRESS sequence to separately measure the contributions of NAA and NAAG in human brain spectra during a functional experiment using visual stimulation. The paradigm used consisted of one off block of 5min20s followed by an on block and another off block, both with 1...

Full description

Saved in:
Bibliographic Details
Main Authors: Landim , Ricardo C. G., Edden , Richard A. E., Foerster , Bernd, Li , Li M., Covolan , Roberto J. M., Castellano , Gabriela
Format: Online
Language:Portuguese
Published: Universidade Estadual de Campinas 2012
Subjects:
Online Access:https://econtents.sbu.unicamp.br/eventos/index.php/phyproceedings/article/view/3213
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1864358285306494976
author Landim , Ricardo C. G.
Edden , Richard A. E.
Foerster , Bernd
Li , Li M.
Covolan , Roberto J. M.
Castellano , Gabriela
author_facet Landim , Ricardo C. G.
Edden , Richard A. E.
Foerster , Bernd
Li , Li M.
Covolan , Roberto J. M.
Castellano , Gabriela
author_sort Landim , Ricardo C. G.
collection Portal de Eventos Científicos da UNICAMP
container_reference Physicae Proceedings; Vol. 1 No. 1 (2012): Proceedings XI Young Researchers Meeting ; 1-2
description In the present work we used a MEGA-PRESS sequence to separately measure the contributions of NAA and NAAG in human brain spectra during a functional experiment using visual stimulation. The paradigm used consisted of one off block of 5min20s followed by an on block and another off block, both with 10min40s, tested on 8 healthy subjects. Visual stimuli consisted of a radial black-white checkerboard flickering at 8 Hz. Because resulting NAA/NAAG peaks at 2.5ppm are small and have undefined shapes, the pre-processing and quantification steps are complex. The phase and frequency corrections seemed to work for some spectra within a scan but not for all, and therefore a possible solution might be to perform case-to-case corrections. Averaging spectra over subjects seemed to give an acceptable SNR for the NAA experiment, but not for the NAAG experiment, for which the 2ppm residue stayed as visible as the peak of interest at 2.5ppm. Specific frequency corrections for this experiment have to be investigated more thoroughly. Quantification with AMARES resulted in large quantification errors, which did not allow assessment of possible stimulus-associated changes. These errors were expected due to the undefined shape problem.
first_indexed 2025-10-08T13:49:11Z
format Online
id ojs-article-3213
institution Universidade Estadual de Campinas
issn 2236-7535
language por
last_indexed 2025-10-08T13:49:11Z
publishDate 2012
publisher Universidade Estadual de Campinas
record_format ojs
spelling ojs-article-32132020-05-15T15:30:07Z Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence Landim , Ricardo C. G. Edden , Richard A. E. Foerster , Bernd Li , Li M. Covolan , Roberto J. M. Castellano , Gabriela NAA NAAG In the present work we used a MEGA-PRESS sequence to separately measure the contributions of NAA and NAAG in human brain spectra during a functional experiment using visual stimulation. The paradigm used consisted of one off block of 5min20s followed by an on block and another off block, both with 10min40s, tested on 8 healthy subjects. Visual stimuli consisted of a radial black-white checkerboard flickering at 8 Hz. Because resulting NAA/NAAG peaks at 2.5ppm are small and have undefined shapes, the pre-processing and quantification steps are complex. The phase and frequency corrections seemed to work for some spectra within a scan but not for all, and therefore a possible solution might be to perform case-to-case corrections. Averaging spectra over subjects seemed to give an acceptable SNR for the NAA experiment, but not for the NAAG experiment, for which the 2ppm residue stayed as visible as the peak of interest at 2.5ppm. Specific frequency corrections for this experiment have to be investigated more thoroughly. Quantification with AMARES resulted in large quantification errors, which did not allow assessment of possible stimulus-associated changes. These errors were expected due to the undefined shape problem. Universidade Estadual de Campinas 2012-03-29 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf https://econtents.sbu.unicamp.br/eventos/index.php/phyproceedings/article/view/3213 Physicae Proceedings; Vol. 1 No. 1 (2012): Proceedings XI Young Researchers Meeting ; 1-2 Physicae Proceedings; v. 1 n. 1 (2012): Proceedings XI Young Researchers Meeting ; 1-2 2236-7535 por https://econtents.sbu.unicamp.br/eventos/index.php/phyproceedings/article/view/3213/3152 Copyright (c) 2012 Physicae
spellingShingle Landim , Ricardo C. G.
Edden , Richard A. E.
Foerster , Bernd
Li , Li M.
Covolan , Roberto J. M.
Castellano , Gabriela
NAA
NAAG
Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title_full Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title_fullStr Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title_full_unstemmed Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title_short Processing of NAA and NAAG edited spectra acquired using the MEGA-PRESS sequence
title_sort processing of naa and naag edited spectra acquired using the mega-press sequence
topic NAA
NAAG
url https://econtents.sbu.unicamp.br/eventos/index.php/phyproceedings/article/view/3213
work_keys_str_mv AT landimricardocg processingofnaaandnaageditedspectraacquiredusingthemegapresssequence
AT eddenrichardae processingofnaaandnaageditedspectraacquiredusingthemegapresssequence
AT foersterbernd processingofnaaandnaageditedspectraacquiredusingthemegapresssequence
AT lilim processingofnaaandnaageditedspectraacquiredusingthemegapresssequence
AT covolanrobertojm processingofnaaandnaageditedspectraacquiredusingthemegapresssequence
AT castellanogabriela processingofnaaandnaageditedspectraacquiredusingthemegapresssequence